| Moc cieplna | 2 - 100 kW |
| Wydajność | 150 - 8500 m3/h |
| Masa | 11,3 - 38 kg |
| Kolor | srebrno - grafitowy |
| Obudowa | stal + tworzywo |
| Masa [kg] | FB 9 | FB 15 | FB 25 | FB 45 | FB 65 | FB 95 |
|
urządzenia |
11,3 | 12,0 | 16,9 | 18,1 | 20,4 | 34,5 |
|
urządzenia napełnionego wodą |
12,0 | 13,2 | 17,9 | 20,1 | 23,1 | 38,0 |
| Wymiary [mm] | FB 9S(M) | FB 15S(M) | FB 25 | FB 45 | FB 65 | FB 95 |
|
A |
500(500) | 500(500) | 600 | 600 | 600 | 600 |
|
B |
540(540) | 540(540) | 640 | 640 | 640 | 1175 |
|
C |
525(525) | 525(525) | 610 | 610 | 630 | 610 |
|
D |
335(275) | 335(275) | 350 | 350 | 370 | 350 |
|
E |
345(345) | 345(345) | 440 | 440 | 440 | 440 |
| Zasięg strumienia powietrza [m] | FB 9 | FB 15 | FB 25 | FB 45 | FB 65 | FB 95 |
|
L* |
14,0 | 14,0 | 26,0 | 24,0 | 22,0 | 33,0 |
| * Zasięg poziomy strumienia izotermicznego, przy prędkości granicznej 0,5 m/s |
![]() ![]() |
| FB 9/15S | FB 9/15M | FB 25/45/65 | FB 95 | |||||||||||
|
Zasilanie |
230v/50Hz | |||||||||||||
|
Pobór prądu |
0,4A | 0,25A | 1,2A | 2,4(2x1,2)A | ||||||||||
|
Pobór mocy |
92W | 57,5 | 280W | 560(2X280)W | ||||||||||
|
IP |
54 | |||||||||||||
|
Klasa izolacji |
F | |||||||||||||
|
Poziom ciśnienia akustycznego* |
45dB(A) | 45dB(A) | 51dB(A) | 53dB(A) | ||||||||||
|
Max. temp. wody grzewczej |
95oC | 95oC | 130oC | 130oC | ||||||||||
|
Max. ciśnienie robocze |
1,6MPa | |||||||||||||
|
Przyłącze |
1/2" | 1/2" | 3/4" | 3/4" | ||||||||||
| * Poziom ciśnienia akustycznego podano dla pomieszczenia o średniej zdolności pochłaniania dźwięku, objętości 1500m3,w odległości 5m od urządzenia. |
| LEO FB 9 | LEO FB 15 | LEO FB 25 | ||||||||||||||
| V = 2000 m3/h | V = 2000 m3/h | V = 4 400 m3/h | ||||||||||||||
| Tp1 | PT | Qw | Δpw | Tp2 | PT | Qw | Δpw | Tp2 | PT | Qw | Δpw | Tp2 | ||||
| oC | kW | I/h | kPa | oC | kW | I/h | kPa | oC | kW | I/h | kPa | oC | ||||
| Tw1/Tw2 = 90/70 | ||||||||||||||||
| 0 | 8,9 | 392 | 2,3 | 14,5 | 17,4 | 769 | 6,9 | 28,5 | 25,4 | 1121 | 11,7 | 16,0 | ||||
| 5 | 8,2 | 363 | 2,0 | 19,0 | 16,1 | 711 | 6,0 | 32,0 | 23,5 | 1037 | 10,1 | 20,0 | ||||
| 10 | 7,6 | 333 | 1,7 | 23,0 | 14,8 | 655 | 5,2 | 35,5 | 21,6 | 953 | 8,7 | 24,0 | ||||
| 15 | 6,9 | 304 | 1,5 | 27,0 | 13,6 | 599 | 4,4 | 38,5 | 19,7 | 871 | 7,4 | 28,0 | ||||
| 20 | 6,3 | 276 | 1,2 | 31,0 | 12,3 | 544 | 3,7 | 41,5 | 17,9 | 790 | 6,2 | 32,0 | ||||
| Tw1/Tw2 = 80/60 | ||||||||||||||||
| 0 | 7,5 | 331 | 1,8 | 12,0 | 14,9 | 656 | 5,3 | 24,5 | 21,6 | 950 | 8,9 | 13,5 | ||||
| 5 | 6,9 | 302 | 1,5 | 16,0 | 13,6 | 599 | 4,5 | 28,0 | 19,7 | 867 | 7,5 | 17,5 | ||||
| 10 | 6,2 | 273 | 1,3 | 20,0 | 12,4 | 544 | 3,8 | 31,0 | 17,9 | 785 | 6,3 | 21,5 | ||||
| 15 | 5,6 | 244 | 1,0 | 25,0 | 11,1 | 489 | 3,1 | 34,5 | 16,0 | 704 | 5,1 | 25,5 | ||||
| 20 | 4,9 | 216 | 0,8 | 29,0 | 9,9 | 435 | 2,5 | 37,5 | 14,2 | 624 | 4,1 | 29,5 | ||||
| Tw1/Tw2 = 70/50 | ||||||||||||||||
| 0 | 6,2 | 269 | 1,3 | 10,0 | 12,4 | 542 | 3,9 | 20,5 | 17,8 | 779 | 6,4 | 11,0 | ||||
| 5 | 5,5 | 240 | 1,0 | 14,0 | 11,1 | 487 | 3,2 | 23,5 | 15,9 | 697 | 5,2 | 15,0 | ||||
| 10 | 4,8 | 211 | 0,8 | 18,0 | 9,9 | 432 | 2,6 | 27,0 | 14,1 | 617 | 4,2 | 19,0 | ||||
| 15 | 4,2 | 182 | 0,6 | 22,0 | 8,6 | 378 | 2,0 | 30,0 | 12,3 | 537 | 3,2 | 23,0 | ||||
| 20 | 3,5 | 153 | 0,5 | 26,0 | 7,4 | 324 | 1,6 | 33,0 | 10,5 | 457 | 2,4 | 27,0 | ||||
| LEO FB 45 | LEO FB 65 | LEO FB 95 | |||||||||||||
| V = 4100 m3/h | V = 3900m3/h | V = 8500m3/h | |||||||||||||
| Tp1 | PT | Qw | Δpw | Tp2 | PT | Qw | Δpw | Tp2 | PT | Qw | Δpw | Tp2 | |||
| oC | kW | I/h | kPa | oC | kW | I/h | kPa | oC | kW | I/h | kPa | oC | |||
| Tw1/Tw2 = 90/70 | |||||||||||||||
| 0 | 46,8 | 2067 | 17,5 | 31,5 | 64,6 | 2669 | 36,8 | 46,0 | 100,1 | 4418 | 55,7 | 32,5 | |||
| 5 | 43,3 | 1911 | 15,2 | 34,5 | 60,2 | 2464 | 32,0 | 48,5 | 92,7 | 4091 | 48,3 | 36,0 | |||
| 10 | 39,8 | 1758 | 13,0 | 38,0 | 55,4 | 2272 | 27,6 | 50,5 | 85,4 | 3771 | 41,5 | 39,0 | |||
| 15 | 36,4 | 1607 | 11,0 | 41,0 | 50,1 | 2084 | 23,6 | 53,0 | 78,3 | 3456 | 35,3 | 42,0 | |||
| 20 | 33,1 | 1459 | 9,2 | 44,0 | 46,2 | 1899 | 19,9 | 55,0 | 71,3 | 3146 | 29,7 | 45,0 | |||
| Tw1/Tw2 = 80/60 | |||||||||||||||
| 0 | 40,1 | 1762 | 13,4 | 27,0 | 56,1 | 2288 | 28,7 | 40,0 | 86,3 | 3790 | 43,0 | 28,0 | |||
| 5 | 36,6 | 1610 | 11,4 | 30,0 | 51,3 | 2097 | 24,5 | 42,0 | 79,0 | 3470 | 36,5 | 31,0 | |||
| 10 | 33,2 | 1459 | 9,5 | 33,0 | 46,7 | 1909 | 20,7 | 44,5 | 71,8 | 3156 | 30,7 | 34,0 | |||
| 15 | 29,9 | 1312 | 7,8 | 36,0 | 42,1 | 1725 | 17,2 | 46,5 | 64,8 | 2847 | 25,4 | 37,0 | |||
| 20 | 26,5 | 1166 | 6,3 | 39,0 | 37,6 | 1543 | 14,1 | 48,5 | 57,9 | 2543 | 20,6 | 40,0 | |||
| Tw1/Tw2 = 70/50 | |||||||||||||||
| 0 | 33,3 | 1459 | 9,8 | 22,5 | 47,1 | 1919 | 21,5 | 33,5 | 72,4 | 3167 | 31,7 | 23,5 | |||
| 5 | 29,9 | 1309 | 8,1 | 25,5 | 42,5 | 1731 | 17,9 | 35,5 | 65,2 | 2854 | 26,2 | 26,5 | |||
| 10 | 26,6 | 1162 | 6,5 | 28,5 | 37,9 | 1547 | 14,6 | 38,0 | 58,2 | 2545 | 21,3 | 29,5 | |||
| 15 | 23,2 | 1017 | 5,1 | 31,5 | 33,4 | 1366 | 11,6 | 40,0 | 51,2 | 2242 | 16,9 | 32,5 | |||
| 20 | 20,0 | 874 | 3,9 | 34,5 | 28,9 | 1187 | 9,1 | 42,0 | 44,4 | 1942 | 13,0 | 35,5 | |||
| V - przepływ powietrza PT - moc grzewcza Tp1 - temperatura powietrza na wlocie do aparatu Tp2 - temperatura powietrza na wylocie z aparatu |
Tw1 - temperatura wody na zasilaniu wymiennika Tw2 - temperatura wody na powrocie z wymiennika Qw - strumień przepływu wody grzewczej Δpw - spadek ciśnienia wody w wymienniku |
| Dane techniczne dotyczące zasilania wodą o innych parametrach otrzymasz w biurze handlowym. |